LCU-ONE CAN connected to MXL QM and EVO3 QM

User Manual

Release 1.04

The layer will be modified as shown below and as many additional layers as many lambda
probes have been added appear.

In case serial number has not been get, press “Get serial number from a connected
expansion” button.
Warning: this operation is necessary to be able to transmit the configuration to the logger.

LCU-ONE

layer is shown above.

On top

Name of expansion configuration

(6 characters max.) and serial number fields.

Inserting a configuration name the layer label is modified live.

Central in the page

a table shows LCU-ONE channels. The table has 7 columns.

Enabled/Disabled

: shows the channel status (enabled/disabled) and can be

modified checking or un-checking the related checkbox. LCC_lambda (lambda
value) and LCC_AFR (AFR value) channels are enabled by default.

Channel name

: shows the channel name and can be modified double clicking on

the cell, which becomes editable.

Sampling frequency

: shows the channel sampling frequency and can be set

selecting the desired value from the pop up menu that appears double clicking on
the cell (accepted values are from 1 to 50 Hz).

Sensor Type

: shows the sensor installed on that channel and cannot be modified.

Measure Unit

: shows the selected unit of measure of that channel and can be

modified double clicking on the cell.

Low/High scale

: shows the channel high and low scale and can be modified double

clicking on the cells, which become editable.

Under

the table is “Multiplier to calculate AFR from lambda” field. It allows the user to

change the used fuel and to insert a new one. Select the used fuel to see its AFR value.