AiM MyChron3 Basic User Manual

Page 33

Advertising
background image

33

Replaying

detailed data

for the lap

If you wish to replay detailed data for a lap, choose Manual or

Automatic replay.

Automatic lap replay: while in general display mode, press

MEM; then, using MENU/<< or >> choose the lap you wish to

see and then press MEM twice: the system will automatically

replay the graphic and decimal RPM, thermocouple

temperature and lap time from start to finish in time intervals

of one-tenth of a second ( 10 Hertz

→ 10 data points per

second ).

To stop the automatic lap replay press MEM. To return to

general display mode press VIEW again.

Manual lap replay: to manually step through the detailed lap

data, while the system is in general display mode, press MEM;

then, using MENU/<< or >> choose the desired lap and then

press MEM twice. The system will go to the “automatic lap

replay” mode.

Press >> or MENU/<< to stop the automatic replay; use

MENU/<< to decrease the progressive lap time by one-tenth

of a second and >> to increment the progressive lap time by

one-tenth of a second.

Press MEM, to return the system to “automatic lap replay”

mode. To return to general display mode press VIEW.