Brady PAM 3000 User Manual

Page 55

Advertising
background image

55

Printer-Applicator-System PAM 3000

Warning Sensor Ribbon End

NOTICE !

The warning sensor ribbon end is only analyzed by the printer electronics if the

warning sensor label end is also installed.

Adjustment

With this setting the threshold diameter 34 to 41 mm for the warning message can be

adjusted.

1. Slide a transfer ribbon roll (6) with the intended threshold diameter onto the media

supply hub.

2. Switch on the printer. The sensor (3) sends out a beam (5). If the ribbon roll does not

interrupt the path of the beam, the beam is mirrored at the reflective foil (7) and

detected again by the sensor. In that case the LED at the sensor is on.

3. Loosen the screws (1) and move the sensor holder to the right as far as possible.

The LED at the sensor is off.

4. Slowly move back the sensor holder to the left until the LED at the sensor goes on.

5. Tighten the screws (1).

Fig. 14g Warning sensor ribbon end

Mounting

1. Switch off the printer

2. Attach the sensor holder (2) with the warning sensor ribbon end (3) to the mounting

plate using the screws (1).

3. Plug the cable (4). For that the printer has a 3-pin connector at the side of the frame.

4. The contents of delivery include a reflective foil (7).

Remove the covering foil from the glued surface and stick the reflective foil (7) onto the

brake (8) below the ribbon hubs as shown in fig.14g. Make sure that the distance

between the reflective foil and the mounting plate (9) is about 15 mm.

5

6

8

1

2

3

4

9

7

15

15

20

7

8

4

Advertising