STEP 8

Turn off supply power before wiring ALL200RM motor switch. Turn off motor switch in square box. Wire

motor switch with 110V wiring. The 110V motor feed must be kept separate from 110V light switch leg.

Keep motor and light neutrals separate. Motor neutral is white and 14 gauge. Only wire motor switch at

this time. See Diagram G.

Never wire the ALL200RM improperly. Make sure electricity is turned off when installing and/or

performing maintenance on the ALL200RM. Improper wiring and/or electricity could cause death,

personal injury, and/or property damage.

14 Gauge Motor Neutral

14 Gauge Motor Hot

110V House Hot

For Motor

110V House Neutral

For Motor

Diagram G

Light

Motor

Do Not Wire Light

Switch At This Time

12 Gauge Light Hot

12 Gauge Light Neutral