Gld-ar84 expander audiorack – Allen&Heath GLD-80 User Manual

Page 16

Advertising
background image

GLD User Guide

16

AP8561 iss.4

GLD-AR84 Expander AudioRack

AR84 plugged into the GLD Mixer:

Inputs

33-40

Outputs

17-20







Input sockets 8 balanced XLR inputs for

microphone and line level sources. The preamps
are built into the AR84 rack and their Gain, Pad
and 48V phantom power is remote controlled
from the GLD console via the EXPANDER link.
The output of the analogue preamps are
converted to digital format and transported via a
Cat5 cable to be processed and mixed at the
GLD mixer.

Any input can be patched to any channel using
the

I/O

or

Preamp

screens.

The sockets are not numbered. This is because
the number depends on where the AR84 is
plugged into the GLD system. Write-on blocks
are provided for you to label the sockets.

Output sockets 4 balanced XLR outputs

operating at nominal +4dBu line level. Any GLD
signal can be patched to any socket using the
console

I/O

screen. The default Template Shows

provide a logical mapping of these sockets to get
you started.

The sockets are not numbered. This is because
the number depends on where the AR84 is
plugged into the GLD system. Write-on blocks
are provided for you to label the sockets.

The socket identification is shown in the diagram
below:

EXPANDER port CAT5 cable link to

connect the AR84 expander to the EXPANDER
port on the AR2412 AudioRack or GLD Mixer.

Note that the EXPANDER link is not

compatible with the iLive ACE connection.

Kensington security slot To attach a

‘Kensington lock’ standard anti-theft cable and
lock if required.

Fan A low noise fan inside the rack ensures

air movement to keep the circuits and internal
components within operating temperature range.

Ensure good ventilation at the back of the

rack. Read the safety instructions printed on the
panel and the Safety Sheet packed with the unit.

Mains cable clip You can secure the cable

in place using the plastic P-clip. Use a T20 Torx
screwdriver to refit the screw.

Mains power input IEC connector, fuse

and power ON/OFF push switch for the built-in
universal voltage power supply unit. This
accepts worldwide voltages from 100 to 240V AC
50/60Hz. Check that you have received the
correct mains lead for your territory.





Socket numbering

AR84 plugged into the AR2412 main AudioRack:

Inputs

25-32

Outputs

13-16



