Network port, Communications port options, Rs232 – Allen&Heath iDR-4 User Manual

Page 43: Sysnet, Pl-anet port, Dr-link port, Idr-switch inputs x24, Idr-switch logic outputs x16, Power supply, Mechanical

Advertising
background image

iDR-4 User Guide

43

Network Port

For system configuration and control using iDR
System Manager and PL Client software
RJ45 TCP/IP Ethernet
MDI/X switch for hub or direct to PC connection
Set DHCP on/off, IP, subnet mask, gateway address
CAT5 UTP cable up to 100 metres (330 feet)

Communications Port Options

Always available – TCP/IP network, DR-Link
Selectable combinations:
RS232

+

SysNet

RS232

+

PL-Anet

SysNet

+

PL-Anet

Available ports indicated by active LEDs

RS232

Uses PPP dial-up connection
Settings Host, Client IP address, username, password
9pin D male
Baud rate 115200, 8N1
Cable length <3 metres (10 feet)
For connection to modem or PC
Use standard 9pin female to male cable to modem
Use 9pin female to female null modem cable to PC

SysNet

Remote parameter control using third party controllers
9pin D female, RS232
Baud rate 19200, 8N1
Cable length <3 metres (10 feet)
Refer to Allen & Heath iDR SysNet protocol

PL-Anet Port

Serial port for daisy chained Allen & Heath PL
intelligent remote controllers
Proprietary Allen & Heath control protocol
RJ45 RS485 with +20V DC ‘phantom’ power
Requires end-of-line termination
CAT5 STP cable, follows EIA/TIA 568B standard
Refer to Allen & Heath PL Calculator spreadsheet for
permissible lengths and PL device combinations

DR-Link Port

Serial control of iDR expander units
Proprietary Allen & Heath control protocol
RJ45 connector
IN and OUT ports provided on expanders to allow
daisy chaining through multiple units
CAT5 STP cable up to 300 metres (1000 feet)

iDR-switch Inputs x24

Contact closure to connect pin to ground
Opto-isolated via 2k2 ohm from internal +10V supply
Sink current 5mA,
Maximum cable resistance 1k ohm
3x 10way Phoenix connectors, 8 switches per 10way
Mating screw terminal plugs supplied
Ground screws provided for cable shields

iDR-switch Logic Outputs x16

Opto-isolated open collector
Floating collector (+) and emitter (-) terminals
Internal DC source provided +10V 500mA total max
External DC supply maximum +24V
Up to 200mA current sink per output
Ground screws provided for cable shields

Power Supply

Universal mains input switched mode design
IEC 3pin, country dependent mains lead supplied
Rear panel power on/off switch
AC mains input 100-240V AC 50/60Hz
Variable speed cooling fan in iDR-4
iDR-4
75VA max, T1.6AL 20mm fuse
iDR-in, iDR-out 25VA max, T500mAL 20mm fuse
iDR-switch 15VA max, T500mAL 20mm fuse

Mechanical

19” rack or stand alone desk/shelf mount
Removable rack ears, press-in rubber feet

Width x Depth x Height

iDR-4

1U rack 483 x 350 x 44mm

19”

x

13.8”

x

1.7”

Desk

440

x

350

x

48mm

17.3” x 13.8” x 1.9”

Weight

5kg,

11

lbs

iDR-in, iDR-out 1U rack 483 x 232 x 44mm
19”

x

9.1”

x

1.7”

Desk

443

x

232

x

48mm

17.4” x 9.1” x 1.9”

Weight

3.5kg,

7.7

lbs

iDR-switch

1U rack 483 x 144 x 44mm

19”

x

5.7”

x

1.7”

Desk

443

x

144

x

48mm

17.4” x 5.7” x 1.9”

Weight

2.2kg,

5

lbs

Allow extra 75mm (3”) depth for connectors

Advertising
This manual is related to the following products: