Installation of tek track to an outlet box – Altman Lighting Track Lighting: GLOBALtrac tec 2-circuit / 2-neutral track system User Manual

Page 6

Advertising
background image

Outlet Box

Outlet Box Canopy Cover

(GES 15)

FEEDS

TEK 11, 12, 14, 34

39, 40, 38

N

L

1

L

2

N

2

1

Ground

STEP 1.
Remove the knock-out hole provided on the back side of the feed connector. Remove feed connector cover.
STEP 2.
Pass the supply, neutral and ground wires through the canopy cover.
STEP 3.
Attach feed connector to track (NOTE: track is polarized and feed connector will only fit one end of track). Pass wires through hole on feed and

mount track to ceiling using toggle bolts or screws.
STEP 4.
ALWAYS CONNECT GROUND WIRE TO GREEN GROUND TERMINAL. Connect live conductors to the appropriate terminal marked "L1", or

"L2". Connect neutral conductors to the appropriate terminal marked "N1" or "N2".
STEP 5.
Replace feed connector cover plate

INSTALLATION OF TEK TRACK TO AN OUTLET BOX

Advertising