Pro Control High Warning Set Point

To adjust the high warning set point, press and release the WARN button. The warning light will begin to flash and the pointer will move to the

previous high warning set point signifying that warning set mode has been selected. Once in set mode, press the WARN button to move the

pointer down, or press the PEAK button to move the pointer up. Three seconds after the last button press, the warning light will stop blinking

and the pointer will return to the current reading. The warning set points are retained when power is removed from the gauge.

Pro Control High Over Warn Set Point

To adjust the high over warn set point, press and hold the WARN button. After three seconds the warning light will begin to flash and the

pointer will move to the previous high over warning set point signifying that over warn set mode has been selected. Release the warn button.

Once in set mode, press the WARN button to move the pointer down, or press the PEAK button to move the pointer up. Three seconds after

the last button press, the warning light will stop blinking and the pointer will return to the current reading. The over warn set points are retained

when power is removed from the gauge.

Pro Control Low Warning Set Point

To adjust the low warning set point, press and hold the WARN button, and while still holding the WARN button, press and release the PEAK

button. The warning light will begin to flash and the pointer will move to the previous low warning set point signifying that warning set mode has

been selected. Once in set mode, press the WARN button to move the pointer down, or press the PEAK button to move the pointer up. Three

seconds after the last button press, the warning light will stop blinking and the pointer will return to the current reading. The warning set points

are retained when power is removed from the gauge.

Pro Control Low Over Warn Set Point

To adjust the low over warn set point, press and hold the WARN button, and while still holding the WARN button, immediately press and hold

the PEAK button. After three seconds the warning light will begin to flash and the pointer will move to the previous low over warning set point

signifying that over warn set mode has been selected. Release both buttons. Once in set mode, press the WARN button to move the pointer

down, or press the PEAK button to move the pointer up. Three seconds after the last button press, the warning light will stop blinking and the

pointer will return to the current reading. The over warn set points are retained when power is removed from the gauge.

Change Backlight Color

To change the backlight color:

With power off, press and hold the warning button. Apply power to the gauge. Release the WARN button. Press and release the PEAK button.

The pointer will move to half scale and the dial will illuminate with the current Backlight Color. Press and hold the PEAK button to cycle through

the available colors. Once you have selected the desired color, release PEAK and don’t press any buttons for about three seconds. The dial

will flicker white several times to indicate the desired setting has been saved and the gauge will return to normal operation with your new color

selection. Color selections are saved when power is off.

Change Low Warn Color

(Region A color)
Warn Color Set Mode:

With power off, press and hold the WARN button. Apply power to the gauge. Release the WARN button. The pointer will be at the stop pin and

the dial illumination will be off. Press and release the WARN button to cycle between HIgH warn color set and LOW warn color set modes. In

High Warn color set mode, the pointer will move to full scale and the dial will illuminate with the current High Warn color. In Low Warn color set

mode, the pointer moves to the minimum position and the dial will illuminate with the current Low Warn color.
To change Low Warn Color:

When the Low Warn color set mode has been selected (see above), press and HOLD the WARN button to cycle through the available colors.

Once you have selected the desired color, release the WARN button. Don’t press any buttons for about three seconds. The dial will flicker

white several times to indicate the desired setting has been saved and the gauge will return to normal operation with your new Low Warn color

selection. Color selections are saved when power is off.

Change High Warn Color

(Region C color)
Warn Color Set Mode:

With power off, press and hold the WARN button. Apply power to the gauge. Release the WARN button. The pointer will be at the stop pin and

the dial illumination will be off. Press and release the WARN button to cycle between HIgH warn color set and LOW warn color set modes. In

High warn color set mode, the pointer will move to full scale and the dial will illuminate with the current High Warn color. In Low Warn color set

mode, the pointer moves to the minimum position and the dial will illuminate with the current Low Warn color.
To change High Warn Color:

When the High Warn color set mode has been selected (see above), press and hold the WARN button to cycle through the available colors.

Once you have selected the desired color, release the WARN button. Don’t press any buttons for about three seconds. The dial will flicker

white several times to indicate the desired setting has been saved and the gauge will return to normal operation with your new High Warn color

selection. Color selections are saved when power is off.

Advertising
This manual is related to the following products: