Blocking instructions, Warning, Danger – Autoquip FREIGHTLIFT FLT User Manual

Page 23

Advertising
background image

23



BLOCKING INSTRUCTIONS


7.

After the platform is fully lowered, continue to hold the DOWN button/lowering
valve for an additional 5-10 seconds to relieve the hydraulic system of pressure.

WARNING !

Failure to relieve operating system pressure could result in the sudden
and unexpected release of high-pressure fluids during maintenance
and/or repair of the lift which may result in severe injury or death.



8.

Follow OSHA electrical lock-out/tag-out procedures. Disconnect and tag all
electrical and/or other power sources to prevent an unplanned or unexpected
actuation of the lift.


9.

Once inspection or work is complete, reverse the performance of the steps above
to raise the platform off the maintenance devices and return the devices to their
designated storage positions.

DANGER

!

To avoid personal injury or death, turn off the power and lock out the
power at the primary power disconnect switch before service or
maintenance per OSHA Lock-Out, Tag-Out procedures.