Routine maintenance – Autoquip FREIGHTLIFT FLT User Manual

Page 56

Advertising
background image

56


ROUTINE MAINTENANCE

DANGER

!

To avoid personal injury or death, all maintenance procedures described in
this section should only be performed by qualified service personnel.

DANGER

!

To avoid personal injury or death, do not operate this equipment with
substandard, defective, or missing parts. Contact a local FREIGHTLITE
service representative if a deficiency is found.

WARNING

!

To avoid serious injury or death, GUARDS, INTERLOCKS, and SAFETY
DEVICES must be restored to correct operation when installing parts or
making repairs.


MAINTENANCE SCHEDULE

USAGE

SUGGESTED MAINTENANCE INTERVALS

5 – 10 cycles per week

180 days

5 – 10 cycles per day

90 days

5 – 10 cycles per hour

30 days or as required.

** Time required to perform this maintenance is approximately 1 to 2 man-hours, plus
any repairs that may be required.

DYNAMIC INSPECTION

(FREIGHTLITE running

)


1. Listen for unusual noises. Isolate and check for the cause. Repair if required.

2. Check that the platform carriage is hitting the upper limit stop bolts. Make sure that

the platform carriage is lined up with the upper floor. Adjust the stop bolts, if
required.


3. Check the limit switch and adjust it, if needed.

Advertising