It4000-ab, Troubleshooting, 17 of 28 – BAND-IT IT4000-AB 5/16 Band-Lok Tool User Manual

Page 17: 5/16” band-lok tool

Advertising
background image

Document # I17794 Rev D

© Copyright

BAND-IT-IDEX, Inc. 2009

All rights reserved

www.BAND-IT-IDEX.com

BAND-IT-IDEX, Inc.

A Unit of IDEX Corporation

4799 Dahlia Street Denver, CO 80216-0307 USA

P: 1-800-525-0758 F: 1-800-624-3925

17 of 28

IT4000-AB

5/16” Band-Lok

Tool

Tool fails to cut off clamp tail:

• The Inlet Air Pressure may be low. Check air supply to Air Controller Module. Cut-off

Pressure Gauge should indicate 105 PSI minimum, 110 PSI maximum. See pages 4 - 6 for
air supply requirements.

• The scrap clamp tail from the previous clamp may not have been removed. Press the Reset

Button to release the tension on the clamp and remove the scrap clamp tail.

• The Cutter Blade or Knife may be worn. See below for Cutter Blade inspection and

replacement.

Note: The Flip Cover Tightening Screw and Flip Cover Head Screws are factory tensioned

and will need to have thread locking compound reapplied and be re-tensioned after the quick
release pins are reinstalled upon completion of maintenance.

2. Remove Flip
Cover and
Tension Block
Assembly for
cleaning and
lubrication.

3. Remove the Cutter
Blade Pin and Cutter
Blade.

4. When installing
the Cutter Blade
Pin, use a small
screwdriver to
push the front
gripper toward the
back of the tool.

1. Loosen the Flip
Cover Tightening
Screw and Flip Cover
Head Screws (see
note above)
to remove
both Quick Release
Pins as shown.

Cutter Blade inspection and replacement:

Troubleshooting

Advertising