Symptom

Probable cause

Recommended Fix

Page

Linkage components
damaged, causing
interference

Remove tool left side body and verify linkage mechanism.
Remove and replace damage as required or contact BAND-
IT.

27

Cut-off cylinder seal
damaged or leaking

Remove left side tool body and verify seal integrity

*

Cut off pneumatic air leak

Verify Coiled Hose Assembly is free of air leaks. Remove
handle cover and inspect for leaks on gray anodized valve
assembly and red valve assembly. Inspect for leaks in
pneumatic system.

*

Water or oil in pneumatic
lines.

Purge pneumatic lines and red four way valve assembly.
Install a desiccant air dryer or similar equipment which meets
tool requirements (see manual).

4

Screws holding Cutter Knife
Pin too long or loose

Verify proper length screws and Cutter Knife Pin seated
properly.

23

Coiled hose line is reversed
(i.e. cut off pressure is
actually going to tension
cylinder.

Verify coiled hose air line from right side of control module
enters bottom fitting on tool.

4,5,7

Improper tool use

Verify operator properly trained and familiar with tool manual.

5,7,8,14

Tension setting too low

Adjust Air Controller Module's tension setting per instructions.

4

Improper buckle location or
application

Locate buckle on smallest radius area. Buckle must be
supported underneath during application. Contact BAND-IT
for application verification / recommendation.

15

Tool cuts clamp tail before
reaching full tension.

Verify timing. If required remove right side handle and adjust
Timing Valve. Replace if damaged.

28

Worn Cutter Knife/ Cutter
Blade

Remove and replace Cutter Knife and Cutter Blade. Refer to
maintenance schedule.

17

Air leaks when trigger is not
activated

Listen for air leaks. Check red valve, Air lines, and replace as
required. No air leaks allowed. Remove and replace as
required or contact BAND-IT.

Contact BAND-

IT for

assistance

Control Module air pressure
valve is in "off" position.

Rotate Control Module valve to open position. Verify gauges
read air pressure.

5

Pinched coil hose line

Loosen fitting on coiled hose assembly where it enters tool
body.

4,7

Kinked or pinched air line

Remove right side handle and inspect air lines. Remove and
replace as required.

28

Tension piston interference
with hanger screw holes.

Loosen Hanger Screw on top of tool. Thread engagement
cannot exceed .125 in.

11

Quick disconnect fittings
not positively engaged.

Disconnect and firmly reconnect.

5,8

Tool will not

operate when

trigger is

depressed

Loose clamp

after cut-off

Tool will not cut

off clamp tail -

Continued.

Troubleshooting
Matrix

Advertising