PROBLEM

OBSERVATION

CORRECTION

9) Tool doesn’t cut

off clamp.

- Cut-off cylinder stalls and does not

cut off clamp tail.


- Clamp tail bends and allows tool to

force buckle past cutter blade edge.

- Check for loose or broken cutter blade.

Tighten screws if loose. Replace cutter
blade if broken.

- Reset clamp hold pressure to recommended

pressure.

- If air line supply pressure is below 100 PSI,

stop operation and correct or allow pressure
to rise above 100 PSI.

- Check cut-off cylinder air cushion valve (fig.

14). It might be screwed in too deep.

- Cut-off cylinder piston seals leak. Loosen

nut off of tube Q. If air is still escaping
remove cylinder and replace seals.

- Cut-off cylinder piston rod may be binding.

Shut off air supply and remove tubes B and
Q and operate piston rod by hand to see if it
moves freely. If not, check back-up roller for
.010” clearance or remove cylinder.

- Lubricate between shear hook and cut-off

cam.

10) Tool never

reaches the
selected pull
pressure. Tool
operation may
be erratic in this
portion of the
cycle.

- Pressure observed increases, then

drops rapidly and jumps back up to a
higher pressure.

- Tool cycles to start the clamp holding

cycle before selected pressure is
observed on gauge.

- Increase the clamp pull cycle time to allow

the tool to regulate to the selected pressure.

- Air line pressure may be lower than the

selected pressure. Check and correct.

- Check the system for an air leak.

11) Tool takes

excessive time
for clamp pull-
up.

- Tool pulls the clamp and reaches the

selected holding pressure, then the
operator waits before the tool
operates to the holding and cut-off
cycle.

- Decrease the clamp pull cycle time (fig. 4).

12) Tool does not

tighten clamps

- Selection of higher clamp pull

pressure does not result in tighter
clamps. Excessive amount of air is
exhausting from the quick-exhaust
valve.

- Check for air system leak. Tighten or

replace defective items.


- Pull cylinder seal may be leaking. Operate

tool to stall the cylinder. Remove tube N and
if air is escaping, disassemble pull cylinder
and repair.


- Check to see if gripper level pin is dragging

on the base. Reposition and retighten the
set screw that retains the pin (fig 6).