PROBLEM

OBSERVATION

CORRECTION

13) Tool takes

excessive time
prior to actuation
of cut-off cylinder.

- Tool reaches clamp hold pressure

selected and operator must wait a
second or more before cut-off cylinder
actuates.

- Decrease the actuation time for the cut-off

cylinder (fig. 5).


- Time delay valve may be clogged. Remove

needle valve and observe. If dirty, remove valve,
disassemble and clean.


- Cut-off valve may be sticking. Remove cut-off

valve, disassemble and clean or replace (fig. 5).

14) Tool does not

read clamp hold
pressure
selected.

- Cut-off cylinder actuates before the clamp

hold pressure selected shows on the
gauge.


- Pressure drops below desired pressure

and regulates at a lower pressure.


- Pressure never regulates.

- Increase the actuation time for the cut-off

cylinder.


- Increase the clamp hold pressure.

- Adjust valve. If no response, replace hold

pressure valve.