DANGER

Failure to comply with these Warnings and Instructions

may result in an explosion or fire that may cause property

damage, serious personal injury or death.
DO NOT DISCARD THESE WARNINGS AND INSTRUCTIONS

WARNING

For LP-Gas Only.

Read all instructions prior to installation and use.

Disconnection of old hose assembly or installation of new hose

assembly and leak testing shall take place outdoors in a well

ventilated area.

DO nOt

make modifications to this hose assembly. If this hose

assembly does not fit, return it to the original place of purchase

and obtain the correct hose assembly for your gas appliance.

Examine the new regulator, hoses and fittings for damage.

If damaged, return to the original place of purchase.

Movement of the gas appliance, removal of old hose assembly

and installation of new hose assembly shall only be done when

appliance is cool.

the regulator outlet pressure is factory set. Do not attempt to

adjust or reset regulator. Consult your local LP-Gas supplier

or LP-Gas Serviceman if you think the regulator is not working

properly.

DO nOt

use appliance until leak testing is complete and any

leaks are corrected.

QCC1 Cylinder

Connection

3/8" Flare

Fittings

Guidelines for Removal of Old Hose Assembly

1.) turn burner control knobs to the “off” position and turn

LP-Gas “off” at cylinder by turning cylinder valve handle fully

clockwise.

2.) If this hose assembly is a replacement for a QCC-1 cylinder

connection, disconnect regulator from cylinder valve outlet

by turning the plastic coupling nut counter clockwise until it

disengages from large outside threads on cylinder valve outlet.

3.) If this hose assembly is a replacement for the old style POL

(left hand thread) cylinder connection, disconnect regulator

from cylinder valve outlet by turning POL fitting clockwise.

4.) Using the proper size wrench, disconnect both the 3/8" flare

fitting from the LP-Gas manifold or burner and the 3/8" flare

fitting on the side burner by rotating each fitting counter

clockwise.

Installation Guidelines for New Hose Assembly
1.) Route the hose through any required openings being sure to

avoid any areas that may cause wear or cut the hose. Also

avoid contact with any potential hot surfaces on the appliance.

2.) Connect the 3/8" flare fitting to the LP-Gas manifold or burner

by rotating the fitting clockwise. tighten using the proper size

wrenches.

3.) Connect the 3/8" flare fitting to the side burner by rotating the

fitting clockwise. tighten using the proper size wrenches.

4.) Position the black plastic coupling nut on the regulator hose

assembly to the cylinder valve outlet. Connect the coupling

nut to the large outside threads on the cylinder valve outlet by

holding the regulator in one hand and inserting the nipple into

the cylinder valve outlet. Hand tighten the plastic coupling nut

in a clockwise rotation until the plastic coupling nut comes to a

full stop. Do not cross thread the connection.

Note: this regulator & hose assembly is equipped with a

QCC-1 appliance connection and requires a cylinder equipped

with a valve marked for use with a type 1 connection.

WARNING

When leak testing the connection:

C

onduct leak test outdoors in a well ventilated area.

Do not smoke.

Do not use or permit sources of ignition in the area while

conducting a leak test.

Do not use matches, lighters or flame to check for leaks.

Do not use the appliance until any leaks are co

rrected.

Leak Testing
1.) Before lighting your appliance, check for leaks by applying a

mild soapy water solution to all connections. Slowly open the

cylinder valve and check for leaks. the appearance of bubbles

indicates a leak.

2.) Repair any leaks prior to lighting your appliance. If you cannot

stop a leak by additional tightening of the connection, shut off

the LP-Gas supply at the cylinder valve and have an LP-Gas

service person make the needed repairs.

obtenga el conjunto de manguera correcto para su artefacto

a gas.

• Examine el regulador, las mangueras y los adaptadores nuevos

para verificar que no estén dañados. Si estuvieran dañados,

devuélvalos al lugar original de compra.

• Sólo debe moverse el artefacto a gas, quitarse el conjunto de

manguera viejo e instalar un nuevo conjunto de manguera

cuando el artefacto esté frío.

• La presión de salida del regulador está configurada de fábrica.

no intente ajustar ni reiniciar el regulador. Consulte a su

proveedor local de gas LP o técnico de servicio de gas LP si

cree que el regulador no está funcionando correctamente.

• NO use el artefacto hasta que se finalice la prueba de fugas y

se corrija cualquier fuga presente.

Conexión del

cilindro QCC1

Adaptadores de llama

3/8 de pulg. (9.5 mm)

Kit de regulador y mangera

para parrilla de propano con

quemador lateral

PELIGRO

Si no se cumplen estas advertencias e instrucciones, se

pueden producir una explosión o un incendio que pueden

causar daños materiales, lesiones personales graves o la

muerte.

NO DESECHE ESTAS ADVERTENCIAS E INSTRUCCIONES

ADVERTENCIA

• Para gas LP (propano líquido) únicamente.

• Lea todas las instrucciones antes de instalar y usar.

• La desconexión de un conjunto de manguera viejo o la

instalación de un nuevo conjunto de manguera y la prueba de

fugas deben realizarse al aire libre en un área bien ventilada.

• NO modifique este conjunto de manguera. Si este conjunto de

manguera no calza, devuélvalo al lugar de compra original y

Pautas para quitar un conjunto de manguera viejo
1.) Coloque las perillas de control del quemador en la posición

“off” (cerrado) y el gas LP en la posición “off” (cerrado) en el

cilindro girando la manija de la válvula del cilindro totalmente

hacia la derecha.

2.) Si este conjunto de manguera es un reemplazo para una

conexión de cilindro QCC-1, desconecte el regulador de

la salida de la válvula del cilindro girando la tuerca de

acoplamiento de plástico hacia la izquierda hasta que se

desenrosque de las roscas externas grandes de la salida de la

válvula del cilindro.

3.) Si este conjunto de manguera es un reemplazo para la

conexión del cilindro POL vieja (rosca izquierda), desconecte

el regulador de la salida de la válvula del cilindro girando el

adaptador POL hacia la derecha.

4.) Con una llave del tamaño correcto, desconecte el adaptador

de llama de 3/8 pulg. (9.5 mm) del distribuidor de gas LP o

quemador y el adaptador de llama de 3/8 pulg. (9.5 mm) en el

quemador lateral rotando cada adaptador hacia la izquierda.

Pautas de instalación para un nuevo conjunto de manguera
1.) Pase la manguera sobre cualquier abertura según sea

necesario, asegurándose de evitar cualquier área que cause

desgaste o cortes en la manguera. también evite el contacto

con cualquier superficie del artefacto que pueda estar caliente.

WARNING

• Materials used in the construction of this device may contain

brass (which may contain lead), a chemical known to the

State of California to cause cancer, birth defects, or other

reproductive harm.

• Combustion byproducts produced when using this device

contain chemicals known to the State of California to cause

cancer, birth defects or other reproductive harm.

Advertising