Fire damper, Particle/odor filter, Restraining device – BKI FH-28WM Ventless Hood System User Manual

Page 11

Advertising
background image

Ventless Hood System

Installation

9

Fire Damper

A UL Listed 165

 F fusible link must be installed in the damper assembly located at the top of the unit.

Install as follows:

1. Lift the damper.

2. Place the link on the damper hook.

3. Lower the damper while placing the link onto the stationary hook.

Particle/Odor Filter

1. Remove the filter from the plastic bag.

2. Open the filter door on the front of the unit by rotating the handle counter-clockwise.

3. Observing the “UP” arrows on the filter, with a hand at each front corner, carefully slide the filter

into the unit.

4. Close and latch the door.

Restraining Device

Install restraining device to secure the appliance to the wall. Adjust restraining cable to allow no more
than two inches (2”) of appliance movement.

In the event of an appliance fire, serious injury, property damage or death could
occur if the appliance is not secured to the hood. A restraining device has been
provided to assure that the cooking appliance remains in the proper position under
the hood during normal operation. DO NOT REMOVE THE RESTRAINING
DEVICE!

Adjust restraining cable to allow no more than two inches (2”) of appliance
movement. This adjustment must not allow the appliance to go beyond front edge
of hood.

Advertising