Display indicators, Charging, Charge stage – Blue Sea Systems 7520 P12 Battery Charger LED Remote User Manual

Page 2: Fan mode, Charge output

Advertising
background image

Display Indicators

1. Charging:

SOLID ON (Green): Indicates Charging mode and will operate according to its charging stage.
BLINKING (Green): Transitioning from Standby to a Charging state.
OFF: Standby mode - will not charge a battery or supply current to loads.

2. Charge Stage:

Bulk-

BLINKING (Green): Indicates Bulk stage on all batteries

Absorb -

BLINKING (Green): Indicates Absorb stage on all batteries

Prefloat*-

SOLID ON (Green): Indicates PreFloat stage on any of three batteries

Float -

SOLID ON (Green): Indicates Float stage on all batteries

Equalize:

BLINKING (Yellow): Indicates Equalize stage on any of three battery branches.

3. Fan Mode:

SOLID ON (Green): Indicates fan LOW or HIGH mode.
SOLID ON (Yellow): Indicates fan OFF mode.
BLINKING (Yellow): Indicates that the fan is OFF and the charger is limiting its output current to protect from eventual overheating. If full output is desired, the
Fan Mode needs to be set to LOW or HIGH to keep the charger cool. If the fan is OFF the charger will limit its output based on its internal
temperature sense.

4. Charge Output:

SOLID ON (Green): Charge Output LEDs are used to monitor the output on three batteries and limit the output using the output button. In normal operation, the Charge
Output LEDs show the percentage of the absolute maximum current on each battery. The range of each individual percentage is as follows:

<5%: 0% ≥ output < 5%

10%: 5% ≥ output < 17.5 %

25%: 17.5% ≥ output < 37.5%

50%: 37.5% ≥ output < 62.5%

75%: 62.5% ≥ output < 87.5%

100%: 87.5% ≥ output < 100%

BLINKING (Green): Indicates that the charger is limiting its output. There are two situations where this could occur:

1) The output of the charger is being limited per the user’s output setting.

2) The charger is limiting output to protect itself from overheating. In this situation, the Charge Output will blink alongside the yellow Thermal Regulation Alert.


See P12 Battery Charger User Manual for more details.

P12

7520 BATTERY CHARGER REMOTE

Charge Output

OUTPUT

CHARGING

Charge Stage

BULK

ABSORB

PREFLOAT

FLOAT

EQUALIZE

HIGH

LOW

OFF

Fan Mode

DIM /

1

2

3

100%

75%

50%

25%

10%

<5%

QuickGuide

Alert

AC

1

2

3

DC

1. Charging
2. Charge Stage

BULK
ABSORB
PREFLOAT

FLOAT
EQUALIZE

3. Fan Mode

4. Charge Output

2 of 4

5. Thermal Regulation and

6. Internal Temperature Sensor

7. Battery Temperature Sensor

8. Fan
9. DC Fuse

10. AC Input Voltage

Too High or Low

11. Reverse Polarity

or Short Circuit

12. Hardware Failure,

DC Output Voltage Too High,

or Equalization Overload

13. Fan

14. DIM/Alarm

15. OUTPUT

16. Standby