Installation instructions – Blue Sea Systems 7620 ML-ACR Automatic Charging Relay - 12V DC 500A User Manual

Page 3

Advertising
background image

REMOTE (Red)

A

B

LED

(Yellow)

ISOLATION #1 (Brown)

GROUND (Black)

LED

1

2

START

BATTERY

ENGINE

ML-SERIES

REMOTE

BATTERY

SWITCH

HOUSE

BATTERY

HOUSE

DISTIBUTION

ISOLATION #2 (Green)

ISOLATION #3 (Orange)

2 AMPS

ENGINE
START
SWITCH

ON

OFF

START

3

+8

-7

ENGINE

ENGINE

START SWITCH

ON

OFF

START

ML-SERIES

REMOTE

BATTERY

SWITCH

ML-SERIES

AUTOMATIC

CHARGING

RELAY

LED

NOTE: The remote

switch has two LEDs.

These LEDs operate

simultaneously and

are either both ON

or both OFF.

NOTE: Use circuit protection

only if ACR is not used for

emergency cross-connect.

Engine Isolation

The ML-Series ACR can be configured to automatically open when two engines are simultaneously running

to ensure that two running engines are never electrically connected. Enable this feature to reduce

noise and communication cross-talk between engines, and to maximize total potential alternator output.
To enable Engine Isolation for two engines:

• Connect the brown wire (ISOLATION #1) from the harness to the ON terminal of the start key switch on

one engine. Make this connection through a 2 Amp in-line fuse. This connection must be to the line that

is positive while the engine is normally running.

• Connect the green wire (ISOLATION #2) to ENGINE #2 in the same manner as above.
To enable Engine Isolation for three engines:

• Connect the brown wire (ISOLATION #1) to ENGINE #1, the green wire (ISOLATION #2) to ENGINE #2, and

the orange wire (ISOLATION #3) to ENGINE #3 in the same manner as above.

990180180 Rev.004

page 3 of 4

REMOTE (Red)

A

B

LED

(Yellow)

ISOLATION #1 (Brown)

GROUND (Black)

LED

1

2

START

BATTERY

ENGINE

ML-SERIES

REMOTE

BATTERY

SWITCH

ML-SERIES

REMOTE

BATTERY

SWITCH

HOUSE

BATTERY

HOUSE

DISTRIBUTION

ISOLATION #2 (Green)

ISOLATION #3 (Orange)

2 AMPS

ENGINE
START
SWITCH

ON

OFF

START

ML-SERIES

AUTOMATIC

CHARGING

RELAY

3

+8

-7

LED

NOTE: The remote

switch has two LEDs.

These LEDs operate

simultaneously and

are either both ON

or both OFF.

NOTE: Use circuit protection

only if ACR is not used for

emergency cross-connect.

Installation Instructions

Start Isolation

The ML-Series ACR can be configured to automatically open temporarily (3-5 minutes) when voltage is

sensed on any one of up to three start-isolation inputs. Enable this feature to isolate Start circuits from the

House circuit and prevent starting current transients from interfering with sensitive house electronics.
To enable Start Isolation:

• Connect the brown wire (ISOLATION #1) from the harness to the terminal or wire running from the start

key switch to the starter solenoid. Make this connection through a 2 Amp in-line fuse. This connection

can be made at the start key switch or at the starter solenoid, but must be to the line that is positive only

when cranking the engine. as shown below.
To enable Start Isolation for two or three engines starting from the same battery:

• Connect the green wire (ISOLATION #2) to ENGINE #2 in the same manner as above.

• Connect the orange wire (ISOLATION #3) to ENGINE #3 in the same manner as above.

Start Isolation Installation

Installation Instructions

(continued)

Engine Isolation Installation

Legend

Optional connection

Legend

Optional connection