Fuses & power control – Carbolite VST 17/-- User Manual

Page 14

Advertising
background image


1700° Tube

14

LMF32C – 1.07

7.0 F

USES

&

P

OWER

C

ONTROL

7.1 Fuses

F1 & F2 - see the example circuit diagram.

F1

Supply Fuses:

Supply fuses are not fitted internally unless the furnace is also fitted with a supply cable; when
fitted they are of GEC Safeclip of the type shown.

Customers should fuse at the rating shown.

F2

Control Fuses: 2 Amp type F 30mm x 6mm

Thyristor Fuse:

Ferraz Protistor of the rating shown. Note that, unlike most fuses, protistor fuses

are correctly rated at a higher current than the thyristor they are protecting.

7.2 Power Control

The setting for the power limit parameter in the controller (

OP.Hi

) should be 100% for all models.

The thyristor stacks are set to the secondary (element) maximum currents given in the table.

Model

Phases

volts

supply fuse
rating

type

thyristor
fuse
rating

Current limit
(element
circuit)

VST 17/--/250

1-phase

220-240

25A

NS25

30A

75A