Model 201CRD & 301CRD 240-VAC Advanced oil burners — Instruction manual

Carlin part number MN2301A Rev. 10/21/10

– 3 –

Codes and standards

Certifi cation

201CRD and 301CRD burners are U.L. listed for the U.S. and Canada,
certifi ed to comply with ANSI/UL 296, for use with #1 or #2 heating oil
(per standard ASTM D396).

Burner labels list compliance, when required, with special local, state or
provincial approvals.

Install this burner in accordance with all local codes and

authorities having jurisdiction. Regulations of these authori-
ties take precedence over the general instructions provided
in this manual.

United States installations

Burner/appliance installations in the United States must comply with the
latest editions of NFPA 31 (Standard for the Installation of Oil-Burning
Equipment), ANSI/NFPA 70 (National Electrical Code), and all applicable
local codes.

Canadian installations

Burner/appliance installations in Canada must comply with the latest editions
of CSA B139 (Installation Code for Oil Burning Equipment), CSA standard
C22, Part 1 (Canadian Electrical Code), and all applicable local codes.

Use the selections in Table 1 ONLY when heating appliance

manufacturer specifi c nozzle selection data is not available,
either in the appliance manual or the Carlin OEM Spec Guide.
Follow all instructions provided with the appliance.

Table 1

Apply the guidelines below to select a nozzle when
appliance-specifi c nozzle data is not available from the
manufacturer or in the Carlin OEM Spec Guide. See
notes at end of table for application tips.

General information

1. 201 & 301 Oil nozzles

Burner applications

Follow all instructions in this manual, the primary control data sheet and
the appliance manual.

Verify the burner is correct for the appliance being used and for all ap-
plicable codes/standards.

Damage or shortage claims

The consignee of the shipment must fi le damage or shortage claims im-
mediately against the transportation company.

When calling or writing about the burner:

Please provide us with the UL serial number and burner model number
to assist us in locating information. This information can be helpful when
troubleshooting or obtaining replacement parts.

The fuel unit is factory-set at 150

PSIG

. The

nozzle selected must consider the fuel unit pressure. See
nozzle sizing in Table 4, page 13.