Model 90524A Triple limit or cold-start control — Instructions

Carlin part number MN90524AM Rev. 01/19/09

– 2 –

Where appliance instructions differ from this manual, follow the appliance instructions.

1

Green LED — POWER ON (Lockout, see
page 3)

2

Amber LED — CIRCULATOR ON

3

Amber LED — BURNER ON

4

Thermostat T-T input terminals

5

Terminal strip (back of control)

6

Sensor terminal strip (quick-release style)

7

Differential adjustment (adjusts High Limit
differential when in cold-start operation;
adjusts Low Limit differential when in triple
limit operation) — when in OFF position,
default high and low limit differentials are
used

8

Hidden reset button

9

Low limit adjustment (set to OFF for cold-
start operation)

10

High limit setpoint adjustment

2

1

3

4

10

9

8

5

6

7

90524A components

Figure 1