INSTALLATION

Unpack the holding and heating units. Ensure that all packing
materials and protective plastic has been removed from the
unit. Inspect all components for completeness and condition.


Appliance should be thoroughly cleaned before use. See
CLEANING INSTRUCTIONS, page 7.





Plug the heating unit into a properly grounded NEMA 5-20R
electrical receptacle. DO NOT MODIFY CORD PLUG.


For first time operation of the cabinet, do not load product into
the cabinet. Allow the heat to remove any residual oils which
may adhere to inside metal surfaces. A slight emission of
smoke is common during the first few hours of operation.

NOTE: DO NOT discard the car-
ton or other packing materials until
you have inspected the appliance
for hidden damage and tested it
for proper operation.

Refer to SHIPPING DAMAGE
CLAIM PROCEDURE
on PAGE 3
of this manual.

WARNING:

Risk of personal injury

Installation procedures must be
performed by a qualified techni-
cian with full knowledge of all ap-
plicable electrical codes. Failure
can result in personal injury and
property damage.

CAUTION:

Electrical Shock Hazard

The ground prong of the power
cord is part of a system designed
to protect you from electric shock
in the event of internal damage.
DO NOT cut off the large round
ground prong or twist a blade to fit
an existing receptacle.


IMPORTANT:
Power cord is 10' long.
If necessary, contact a

licensed electrician to install an
appropriate 20 amp electrical cir-
cuit with NEMA 5-20R receptacle.
DO NOT use an extension cord.


IMPORTANT:

Damage to unit due to
being connected to the

wrong voltage or phase is NOT
covered by warranty.

Installation of the HR90 EnduraHeat System:
EnduraHeat and Convection heat combined in a single heat-
ing unit. This unit is heavy and requires 2 people to install or
remove it from the cabinet.

To install, grasp handles on unit and angle it so it slides
through one of the door openings. Fish power cord through
front opening at base of doors. Place heater so that the bot-
tom portion of the convection heater fits into the hole in the
floor of the cabinet and the control panel fits through the front
opening. The base of convection heating unit will hang

through the hole and will be
outside the cabinet, allowing
for air circulation to cool the
fan motor.

Center section:
convection heating

Left & right sections:
EnduraHeat

Control panel

Power Usage:

EnduraHeat Convection

Mode Mode

Volts : 120

120

Watts: 1900

1650

Amps: 16.7

13.8

GROUNDING INSTRUCTIONS

This appliance is equipped with a cord having a grounding wire with a grounding plug which must be plugged
into an outlet that is properly installed and grounded. In the event of an electrical short circuit, grounding re-
duces the risk of electric shock by providing an escape wire for the electrical current.

WARNING-Improper use of the grounding can result in a risk of electric shock. Consult a qualified electri-
cian or service agent if the grounding instructions are not completely understood, or if doubt exists as to whether
the appliance is properly grounded.