Carter-Hoffmann MC243S-2T User Manual

Page 9

Advertising
background image

9

CONTROLLER PROGRAMMING

To enter into program
mode, display must
be in operating mode
and not in a timing
cycle .

NOTE:

Each module

can be programmed
individually.

Rear display cannot be
programmed.

TEMPERATURE
SETPOINT RANGE:
122ºF - 195ºF
(50°C - 91°C)
TEMPERATURE
DEFAULT SETPOINT:
195ºF(91°C)


TIMER RANGE:
1 minute to 9 hours, 59
minutes

NOTE:

While in the

program mode, if no
key is pressed for 10
seconds, any changes
will be saved and the
control returns to nor-
mal operation mode.

NOTE:

The technical content of
this manual, including any
wiring diagrams, sche-
matics, parts breakdown
illustrations and/or adjust-
ment procedures, is
intended for use ONLY
by qualified technical
personnel

.

PROGRAM TEMPERATURE SETPOINT (P1 through P6)

1. Press and hold the TEMP KEY until display flashes.

2. Press INCREASE KEY or the DECREASE KEY to raise or lower

temperature or time setpoint. Each time the key is pressed, setpoint is changed

by

1º.

3. Press TEMP KEY to save changes

PROGRAM TIMERS (P1 through P6)


1. Press and hold TIME KEY until display flashes.


2. Press INCREASE KEY or the DECREASE KEY to raise or lower
time setpoint. Each time the key is pressed, setpoint is changed by one minute.

Hold the key to scroll faster.


3. Press the TIME KEY to save changes and return to “P 1”.

4. To program timers “P 2” through “P 6”:

5. Press INCREASE KEY or DECREASE KEY to select desired
timer program number (“P 2” thru “P 6”).

6. Repeat steps 1 through 3 above for each program.

TO CANCEL TIMER

Press and hold TIME KEY for 2 seconds.

TO CHANGE THE TEMPERATURE SCALE

Press the TEMP KEY until the temperature starts flashing. Then, press both
the up and down arrow buttons (together) until ‘F’ (Fahrenheit) is displayed.

Press the up or down arrow keys to toggle between ºC and ºF.

Once selected, press the TEMP KEY to save and exit.

DIGITAL READOUT

INCREASE KEY

DECREASE KEY

TEMPERATURE KEY

TIME KEY

POWER SWITCH

NOTE:

“P1” must be displayed
before temperature
scale can be changed.
If “P1” is not displayed,
press ARROW KEY to
display “P1.”

Advertising
This manual is related to the following products: