Carter-Hoffmann VCNH2W3S User Manual

Page 6

Advertising
background image

Up and Down Arrow Buttons

Digital Display Readout

Temperature Button

Alarm Button

Heat “ON” Indicator

175

Controller

6

NORMAL OPERATION

Factory default setpoints:
- temperature: 175ºF (80

°C)

- low temp alarm: 140ºF
(60

°C)


Operating ranges:
- temp alarm: 60ºF-140ºF
(16

°C– 60°C)

- air temp: 140ºF-210ºF
(60

°C - 99°C)

CAUTION:
HOT SURFACE

Inner surfaces of the unit
will be very hot during and
after operation. Avoid
touching the cabinet when
loading or removing
product.

OPERATION

1. The power switch is located on the right front edge of the cabi-

net. Turn the power switch ON and let cabinet preheat for 30
minutes. When the cabinet is turned on, the air heater will oper-
ate until the cabinet reaches the air temperature setpoint. The
display will read the actual cabinet temperature. The heat “ON”
light will illuminate when the cabinet temperature is below the
air temperature setpoint and the heating elements are acti-
vated. The controller will flash alternately “LO” and the actual
cabinet air temperature until it reaches the low alarm tempera-
ture setpoint (140ºF).

2. After preheat, load cabinet with food product. Food is held in

1/2 size long pans as that fit into the sliding wire racks inside
the cabinet.

3. When cabinet is not in use, turn power off.

4. Cabinet must be cleaned daily. See cleaning instructions on

page 9.

CONTROL PANEL LAYOUT

On/Off Toggle Switch