99

Undercounter T

emperature Display Board

P/N 0512106

B

Rinse T

est

Pushbutton

A

W

ire Har

ness Plug

for W

ash and Rinse Ther

mistors

C

W

ash T

est

Pushbutton

D

Booster

Temperature

Adjust M4 SETTING ONL

Y

E

W

ash

Temperature

Adjust M4 SETTING ONL

Y

Diagnostics

A -

When testing the circuit board

operation, disconnect the har

n-

ess from this plug. The wash and

rinse displays will display E.

B -

Push and hold the rinse test

pushbutton. A numerical value

of 179-180 should appear

in the rinse temperature display

window indicating the circuit

board is operating nor

mally

.

C -

Push and hold the wash test

pushbutton for 10 seconds

A numerical value of 140

should appear in the wash

temperature display window

indicating the circuit board

is operating nor

mally

.

When per

for

ming diagnostics the values are

displayed in °F even if the display is set for °C.

A F/C Slide switch is provided on the board to change the display from the factor

y default

setting of °F to the optional °C.

D -

Tur

n clockwise to increase the

booster temperature. Full range

is 3/4 tur

ns 180-200°F

. DO

NOT FORCE P

AST THE STOPS.

E -

Tur

n clockwise to increase the

wash temperature. Full range is

3/4 tur

ns 120-160°F

. DO NOT

FORCE P

AST THE STOPS.