Water connections, Drain connections – CHAMPION UL-130 Manual User Manual

Page 17

Advertising
background image

7

Water Connections -

UH130, UH130B, UH230, UH230B

Models UH130B, UH230B

1. All models have a 6 ft. flexible hot water fill hose with a 3/4" female garden hose connector.
2. A 1/2" or larger main incoming supply line should be installed to the dishwasher.
3. A 1/2" or larger shut-off valve should be installed in the water supply line as close to the

dishwasher for servicing.

4. FOR UH230B ONLY:

A pressure regulating valve, PRV, (supplied), must be installed after the shut-

off service valve if the incoming flow pressure exceeds 20-22 psi minimum.

5. FOR UH130B ONLY:

The UH130B has a built-in flow control. The incoming hot water supply

pressure must be between 25-95 psi.

6. The hot water supply must provide a minimum of 140°F/60°C, measured at the dishwasher for

the 40°F/ 22°C rise booster. For the 70°F/39°C rise booster the hot water supply must provide

a minimum of 110°F/43°C measured at the dishwasher.

7. A water hardness of 3 grains/gal (US) [51.3 mg/L] or less is recommended.

Models UH130 and UH230

1. All models have a 6 ft. flexible hot water fill hose with a 3/4" female garden hose connector.
2. A 1/2" or larger main incoming supply line should be installed to the dishwasher.
3. A 1/2" or larger shut-off valve should be installed in the main water supply as close to the

dishwasher as possible for service.

4. FOR UH230B ONLY:

A pressure regulating valve, PRV, (supplied), must be installed after the shut-

off service valve if the incoming flow pressure exceeds 20-22 psi minimum.

5. FOR UH130B ONLY:

The UH130B has a built-in flow control. The incoming hot water supply

pressure must be between 25-95 psi. For Models UH130, and UH230, the hot water supply must

provide a minimum of 180°F/82°C, measured at the dishwasher.

6. A water hardness of 3 grains/gal (US) [51.3 mg/L] or less is recommended.

Model UH130, UH130B, UH230, UH230B - Installation

NOTE

Plumbing connections must comply with national, provincial local plumbing and sanitary codes.

! IMPORTANT !

Make sure that the flexible water supply and drain hoses are not kinked.

Drain Connections

All Models

1. All models have a 6 ft.. 5/8" I.D. drain hose. The maximum drain height connection

must not exceed 3 ft.[0.9 m].

2. A 3/4" hose barb fitting is

strapped to the drain hose to

connect the drain hose to a

wye drain fitting.

.

The service part number for the

hose barb is P/N 0512321.

Advertising