96

P/N 115107 - Condensate Removal Option Installation Instructions

Condensate Removal Shroud Electrical and Plumbing Connections

WARNING

:

Electrocution or serious injury may result when working

on an energized circuit.
Disconnect power at the main breaker or service

disconnect switch before working on the circuit.
Lock-out and tag the breaker to indicate that work is

being performed on the circuit.

(continued from previous page)

1. The condensate removal

shroud fans were prewired

at the factory.

When the shroud is

installed on the top of the

dishwasher, the shroud

wires and their corre-

sponding wires on the

back of the dishwasher

should be in close prox-

imity to each other.

2. Locate the wires and

connect black to black and

white to white.

(See Figures A at right.)

3.

! ATTENTION !

Route the condensate

removal shroud hoses

behind the handle as-

sembly as shown in Figure

A above. The hoses

shown in Figure B

at right have been routed

in front of the handle

assembly, this is incorrect.

4. Referring to Figure B,

note that there are three

hoses preconnected to

the condensate removal

shroud. The hoses are

different lengths to ensure

that the hoses are con-

nected to the correct

locations.

A

Fan Wires

A

DO NOT route the condensate removal shroud hoses

in front of the handle assembly as shown in this photo.

Route the hoses behind the handle assembly against the

rear of the machine.

B

!