Water Connections for Standard Model and Direct Vent Option Model

The incoming hot water line is a 3/4" NPT connection.

! ATTENTION !

A qualified plumber must connect the water supply to the dishwasher in accordance with all

local plumbing and sanitation codes and regulations.

Improper installation will not be covered by the Limited Warranty.

Installation

1. The Standard Model dishwasher and the Direct Vent Option Model

require a single hot water connection

HOT WATER — 3/4" NPT, 110°F/43°C minimum temperature, with a minimum incoming

flowing pressure of 45 PSI measured at the dishwasher before adjusting operating

pressure to 20/25 PSI flowing pressure.

2. A water hardness of 3 grains/gal (US) [51.3 mg/L] or less is recommended.

3. A manual shut-off valve, 3/4" or larger, should be installed in the hot water supply line

as close to the dishwasher as possible for servicing.