Resume on Ring enables telephony devices to access the computer when it is in a power-managed
state. The method used depends on the type of telephony device (external or internal).

NOTE

The use of Resume on Ring and Wake from USB technologies from an ACPI state requires an
operating system that provides full ACPI support.

1.13.2.1 Power Connector

ATX12V-compliant power supplies can turn off the system power through system control. When
an ACPI-enabled system receives the correct command, the power supply removes all non-standby
voltages.

When resuming from an AC power failure, the computer returns to the power state it was in before
power was interrupted (on or off). The computer’s response can be set using the Last Power State
feature in the BIOS Setup program’s Boot menu.

For information about

Refer to

The location of the main power connector

Figure 20, page 56

The signal names of the main power connector

Table 24, page 59

1.13.2.2 Fan Connectors

The function/operation of the fan connectors is as follows:
• The fans are on when the board is in the S0 or S1 state.
• The fans are off when the board is off or in the S3, S4, or S5 state.
• Each fan connector is wired to a fan tachometer input of the hardware monitoring and fan

control ASIC.

• All fan connectors support closed-loop fan control that can adjust the fan speed or switch the

fan on or off as needed.

• All fan connectors have a +12 V DC connection.

For information about

Refer to

The location of the fan connectors

Figure 20, page 56

The location of the fan connectors and sensors for thermal monitoring

Figure 15, page 37

The signal names of the processor fan connector

Table 22, page 58

The signal names of the chassis fan connectors

Table 23, page 58

1.13.2.3 LAN Wake Capabilities

CAUTION

For LAN wake capabilities, the +5 V standby line for the power supply must be capable of
providing adequate +5 V standby current. Failure to provide adequate standby current when
implementing LAN wake capabilities can damage the power supply.

LAN wake capabilities enable remote wake-up of the computer through a network. The LAN
network adapter monitors network traffic at the Media Independent Interface. Upon detecting a