B. Wall Exit Into Metal Tee-Box

1. Mark the plumb line on the wall directly behind the center of the heater. (See Figure 6.)

NOTE: When using 24# ga. minimum blue or black steel pipe, maintain 18" between pipe
and ceiling.

NOTE: Floor protector must be under horizontal pipe exit (See Figure 9. Page 19. )

2. Place the vertical portion of the heater pipe and the elbow in position and project a

point onto the plumb line level with the center of the elbow.

Figure 6

ATTIC

CEILING

"TEE" BOX ASSEM.

CENTER LINE

OF ELBOW

MARK PLUMB LINE

WALL

WALL PASS-THROUGH CONNECTOR

18" MIN.

TEE BOX ASSEM.

CLEAN OUT ACCESS

FLOOR PROTECTOR

3 SHEET METAL SCREWS OR RIVETS

CEILING

ROOF

Figure 5

COLLAR

3 SHEET METAL SCREWS

Figure 5

COLLAR

3 SHEET METAL SCREWS