Perform all inspection procedures listed in 6-month inspection. Pump out sludge in the first and second chambers (if necessary).
If the maximum sludge accumulation has been reached, see description in 6-month inspection.
Make sure to remove the scum on top layer first, then pump out the sludge of each chamber.

INSPECTION AND MAINTENANCE - PUMPING AS NEEDED

Figure 22 - Pump out procedures

Step 1: Remove the scum.

Step 2: Remove the sludge

1)

2)

Sedimentation/separation tank

Vacuum

Step 1: Remove the scum.

Step 2: Remove the sludge

on the filter media.

Step 3: Remove the sludge

under the media while washing

the filter with tap water.

1)

Anaerobic filter tank

Vacuum

Tap water

2)

3)

ATTENTION: Remove the scum first. If you remove the sludge first, the water

level will decrease and the anaerobic filter will be blocked by the scum.

Figure 23 - Cleaning of anaerobic filter tank, remove all scum and sludge.