Important: Always read and follow the instructions.

• 17

Self-Calibration

For machine self-calibration proceed as follows:

- Fit a wheel with steel rim of average dimensions on

the shaft. Example 6" x 14" (± 1")

- Preset the exact dimensions of the wheel mounted.

IMPORTANT !! Presetting of incorrect dimensions

would mean that the machine is not correctly cali-
brated, therefore all subsequent measurements will be
incorrect until a new self-calibration is performed with
the correct dimensions!!

- Perform a spin under normal conditions.

- Add a 4.00 oz (ounce mode) or a 100 gram (gram

mode) calibration weight on the outside in any angular
position.

- Shift the calibration weight straight across to the

inside; keeping the same angular position.

- Rotate the wheel so to have the calibration weight

to the 12 o’clock position.

END OF SELF-CALIBRATION

CANCEL SELF-CALIBRATION IN ANY PHASE.

Display Saver

A display saver function can be enabled which allows

temporarily replacing the information on the display
with moving symbols. This function is activated when
the balancing machine is not used for longer than the
time set in the relevant setup:

Modifies the time expressed in minutes.

CONFIRM

Setting 0, the display saver is automatically disabled.

The display saver is not active in the setup menu of

the balancing machine.

To return to normal functioning of the balancing

machine, press any button or move the wheel.