Caution, 0 installation instructions – COATS 9500 Electro-Hydraulic Tire Changer User Manual

Page 9

Advertising
background image

COATS 9500 Tire Changer • 5

3.0 Installation

Instructions

To install the machine proceed as follows:

A. Before raising the machine, ensure that the chuck

is completely closed, that the chuck arm is lowered
and the tool holder carriage is all the way in (Fig.12).

Fig.12

B. Remove the screws that secure the machine to

the pallet.

Lift the machine only with the two lifting lugs with a

belt or rope of appropriate length and strength.

Do not swing the machine when lifted.

Do not cut the remote unit cord when low-
ering the machine to the ground.

3.1 Electric Installation

All electrical connections shall be performed by a

licensed electrician. All service must be performed by
an authorized service technician.

Check on the plate of the machine that the electrical

specifications of the power source are the same as the
machine.

The machine uses 220VAC, 60 Hz, 3Ph, 22 Amp.

Electrical specifications are clearly marked on a label

at the end of the electric cord.

Before connecting the machine to the power source,

check that the power supply has an efficient grounding
system.

Connect the electric cord of the machine with a cor-

rectly rated plug.

There should be less than 1 Ω between the ground

pin and earth ground.

Never connect the grounding wire to a live terminal.

Check that the power supply has an automatic circuit

breaker with a differential circuit set at 30 mA.

The electric motor operates in a wide voltage range

(plus 10% - minus 7%) and frequency range (50 or 60
cycles) and has a class of insulation suit-able for hot
and moist climates.

3.2 Motor Rotation Check

Once the machine is hooked-up, turn the machine on

using the on/off switch.

Important: Ensure that the rotation direction of the

pump is the same as indicated by the arrow on the
motor cover.

If not, reverse any two phase cables on the plug (i.e.

Reverse the brown and the blue cable).

Any damage caused by the non-application
of the above instructions shall not be cov-
ered by the manufacturer and will void the
warranty.

CAUTION

CAUTION

CAUTION

Note: The outlet installation must be verified by a

licensed electrician before connecting the tire
changer.

Note: The yellow with green wire in the cord is the

grounding wire.

Advertising