Appendix, Trouble shooting appendix, Technical parameters – Brada Appliances YPM-06C User Manual

Page 14

Advertising
background image

-

14-



Please check the air conditioner by yourself referring to the following chart before contacting
professional service.

Trouble Reason

Solution

Is no power supply?

Plug in and turn on the unit.

Is water full?

Drain out the water and restart the unit.

Is the room temperature too high?

Please use only when the room
temperature between 5-40℃

The unit doesn’t

work

Is Timer function activated?

Cancel Timer function

Is the unit in direct sunlight?

Draw the curtains

Is the door or window opened? Is
there any heat source in the room?

Close the window and door. Turn off or
move the heat source.

Is the filter very dirty?

Clean or change the air filter

Is air inlet outlet blocked?

Clear out the blockage.

The unit does

not seem to

perform.

Is the room temperature lower than

setting temperature?

Adjust the setting temperature

The unit noise is

high

Is the unit not on flat place?

Put the unit on flat and hard
place

Compressor

doesn’t work

Is overheat protection of compressor
activated?

Re-start the unit after 3 minutes when
the temperature of compressor is
reduced.

Is the distance too far from the unit?

Is the signal not received by unit?

Use remote control near the unit and
make sure it aims at the remote control
receiver on the unit.

Remote control

doesn’t work

Is the battery exhausted?

Change new battery.


NOTE: Stop running the unit and pull out the plug if the problem is beyond the trouble shooting chart,
and call service center for help. Don’t repair or disassemble the unit by yourself to avoid any damage.

APPENDIX

Technical parameters


Risk of electric shock. Disconnect Power before Servicing Unit

There is no further notice for the change of the parameters above, please refer the exact

parameters base on the rating plate

*Do not dispose this product as unsorted municipal waste. Have refrigerant removed by a

qualified service technician before disposing of this unit .

Air-conditioner

Serial No. ****

MODEL YPM-06C
RATED COOLING

5000BTU

REFRIGERANT/CHARGE R410a/260g
POWER SUPPLY

110-120V/60Hz

RATED CURRENT 7.5A
HIGH/LOW PRESSURE

3.5/1.0MPa

*******

Conforms to UL STD. 484

Certified to CSA STD. C22.2 No.92

NOISE 54dB

(A)

NET

WEIGHT

19kg

DIMENSION(L*D*H)

310*296*850mm

YOAU ELECTRIC CO.,LTD

M

otor-Compressor Thermally Protected

TROUBLE SHOOTING

APPENDIX