Elkhart Brass Copperhead 8593-04 Monitor User Manual

Page 17

Advertising
background image

17

SYSTEM SPECIFICATIONS
Panel Mount Controller

Input power

12/24 VDC (11 VDC to 30 VDC)

RF power output

Meets FCC part 15 requirements for license free operation

Transmitter dimensions

7 5/8” x 3 7/8” x 2 3/8”

Operating temperature range

-40

o

C to +65

o

C, -40

o

F to +150

o

F

Environmental Rating

NEMA 4

FCC ID

QT8PTSS2011

Handheld Controller

Input power

2 AA Batteries (Lithium Recommended)

RF power output

Meets FCC part 15 requirements for license free operation

Transmitter dimensions

6” x 3 1/4” x 1 3/8”

Transmitter weight

10 ½ oz.

Operating temperature range

-40

o

C to +65

o

C, -40

o

F to +150

o

F

Environmental Rating

NEMA 4

FCC ID

QT8PTSS2011

Receiver

Power requirements

Without Converter Assembly 12VDC (11-14VDC)

With Converter Assembly (11-30VDC)

at the controller under full load

Electrical Load

See Table 4 Below

Control current

0.07 A (12V)

Operating temperature range

-40

o

C to +65

o

C, -40

o

F to +150

o

F

Environmental Rating

NEMA 4

Monitor

Left/Right

Up/Down

Nozzle

Run Current*

4.3 A

4.8 A

0.7 A

Stall Current*

14 A

14 A

NA

Current Trip Point*

12.5 A

8 A

4 A

Shock

30 G’s (55 Hz. @ .2” double amplitude)

Vibration

15.5 G’s (55 Hz. @ .05” double amplitude) continuous operation

Drop Test

The handheld controller must meet operating specifications after drop from 1m height onto

concrete surface.

Environmental

All enclosures have a NEMA 4 rating (must withstand a 1” stream of water at 65 GPM from a

distance to 10ft. for five minutes with no water entering the enclosure).

Table 4: Motor Current Specifications

*All current ratings are at 12V

Advertising