Typical all rf install guide – Elkhart Brass Sidewinder Typical All RF Install Guide User Manual

Page 2

Advertising
background image

Typical All RF Install Guide:

Control Components & Accessories

2

4.

5.

6.

A. Follow mounting templates on page

30 of the instruction manual for hole

diameters and dimensions.

B. Drill holes for CAN network and

power cables for each components’

leads behind each component.

C. Mount components to panel using

10-24 x 1/2” screws. Use Loctite 242 or

equivalent.

D. Add a 1A (12VDC)* fuse between

red component lead and positive power

lead.

A. Connect entire CAN network together using 18-22 AWG. Ensure every component connected to the CAN network is connected in between 2 end components that

have CAN termination. Please refer to the BLUE, GREEN, and BLACK lines as the CAN wires below.

*.5A (24VDC)

- Joystick Controller

- OEM Interface Module

A. Install valve into plumbing. Torque

adapter bolts to spec using torque specs

listed to the right

.

7/32” dia.

unless noted

CAN

Network

Wires

18g

98326040 Rev. Rel

B. Add a 30A(12VDC)* fuse between

RED controller lead and positive power

lead. *15A(24VDC)

16g

Handheld Controller / Docking Station

-

1

3

4

2

Tighten Adapter

Bolts using a

cross pattern

25-30 ft-lbs

Before continuing please follow the steps on page 14 of the Sidewinder EXM instruction manual outlining the

Monitor Configuration Tool.

Connect power and

attach battery pack to

Handheld controller.

RF Installation - The cable will run the

length of the RF Module when installed

correctly.

Advertising