Typical All RF Install Guide:

Button Press Logic

4

BUTT

ON LOGIC

JOYSTICK

Button Press Logic: Panel Mount, Handheld, and Joystick

Joystick Layout:

Up

Down

Right

Left

AUX

OSC

Nozzle Pattern

• Fog

• Stream

Valve Position (Trigger)

• Open (Pull)

• Close (Release)

Open

Close

Preset

To Stow

To Oscillate

Left, Right, Up, Down

Fog & Straight Stream

Valve Open & Close

Valve Auto Travel

To Change Valve Preset

Hold <Fog> and <Osc> until monitor begins to stow.

Press the <Osc> button at both extremities of the desired oscillation

pattern.

NOTE: You can manually control nozzle position while in a single

axis oscillation. Example: Up and Down will allow you to manually

control the vertical axis while in a horizontal oscillation. Any

direction in a two axis oscillation will stop the oscillation.

To auto travel OPEN, hold the <Open> button, then press <Close>, and

release both. The valve should fully open automatically. To CLOSE,

hold the <Close> button, then press <Open>, and release both.

Open or close the valve to the desired position. Press and hold the

<Preset> button until the preset light blinks (approx 10 seconds).

These function normally

These function normally

These function normally

Valve Preset

Opens or closes valve to a predetermined position

Horizontally

Vertically

Two Axis Oscillation

Valve Position Buttons

Valve Position LEDs

98326040 Rev. Rel