Problem; monitor will not stop at intended horizontal travel limits.

5.

Disconnect horizontal position sensor connectors J08 & P08. In connector P08

check for hall sensor power (+7.5 to 12 VDC) at terminal 3 (red wire), left/right

sensor signal voltage (+4.5 to 7.5 VDC) at terminal 2 (white wire), and ground at

terminal 1 (black wire).

a) Passed; if all values were within specifications. Move on to step 9b.

b) Failed; one or more values did not meet specifications. Move on to step 6.

6.

Move to the next connector in the harness towards the monitor control module

and check for hall sensor power (+7.5 to 12 VDC) at terminal position C, left/right

sensor signal voltage (+4.5 to 7.5 VDC) at terminal position H, and ground at

terminal position K. (There may be an extension harness or harnesses between

connectors P4 and J4.)

a) Passed; if all values were within specifications replace monitor harness and

retest system.

b) Failed; if all values were not within specifications;

1.

If this connector was on the output pigtail from the monitor

control module then replace the monitor control module, reconnect

harnesses, and go back and repeat step 5.

2.

If this connector was on an extension harness move to next

connector in the harness towards the monitor control module and

check for hall sensor power (+7.5 to 12 VDC) at terminal position C,

left/right sensor signal voltage (+4.5 to 7.5 VDC) at terminal position

H, and ground at terminal position K. If all values were not within

specifications move to next connector in the harness towards the

monitor control module and continue testing until you get the correct

values in which case you replace the previous harness extension or

until you reach the control module and still do not get the correct

values in which case you replace the control module. In either case

reconnect harnesses, and go back and repeat step 5.

Advertising