Problem; monitor will not stop at intended vertical travel limits.

7.

Disconnect vertical position sensor connectors J06 & P06. In connector P06

check for hall sensor power (+7.5 to 12 VDC) at terminal 3 (red wire), left/right

sensor signal voltage (+4.5 to 7.5 VDC) at terminal 2 (white wire), and ground at

terminal 1 (black wire).

a) Passed; if all values were within specifications. Move on to step 9a.

b) Failed; one or more values did not meet specifications. Move on to step 8.

8.

Move to the next connector in the harness towards the monitor control module

and check for hall sensor power (+7.5 to 12 VDC) at terminal position C, up/down

sensor signal voltage (+4.5 to 7.5 VDC) at terminal position J, and ground at

terminal position K. (There may be an extension harness or harnesses between

connectors P4 and J4.)

If this connector was on an extension harness move to next connector in the

harness towards the monitor control module and check for hall sensor power

(+7.5 to 12 VDC) at terminal position C, left/right sensor signal voltage (+4.5 to

7.5 VDC) at terminal position J, and ground at terminal position K. If all values

were not within specifications move to next connector in the harness towards the

monitor control module and continue testing until you get the correct values (in

which case you replace the previous harness extension) or until you reach the

control module and still do not get the correct values (in which case you replace

the control module). In either case reconnect harnesses, and go back and repeat

step 7.

9.

Checking the monitor control modules travel limit function using a jumper.

a) Testing the vertical limits; While moving the monitor up electrically place the

jumper between terminal positions 1 & 2 in connector P06. The monitor

should stop and only allow downward travel until the jumper is removed.

Remove the jumper and repeat the test while going down and the monitor

should stop and only allow upward travel until the jumper is removed.

b) Testing the horizontal limits; While moving the monitor left electrically place

the jumper between terminal positions 1 & 2 in connector P08. The monitor

should stop and only allow travel to the right until the jumper is removed.

Remove the jumper and repeat the test while going right and the monitor

should stop and only allow travel to the left until the jumper is removed.