Elkhart Brass 70133000 Electric Valves User Manual

Page 25

Advertising
background image

25

- If the fuse is ok, replace the power card.


DC output voltage not available at terminals 33 and 34

- De-energize the main power supply and disconnect all wires from terminals 33 and 34.
- Energize the main power supply and check the voltage on terminals 33 and 34. The reading should be

between 23 and 27 VDC.

- If the voltage reading is correct, check the external wiring and the electrical load. It should not exceed

4W.

- If the voltage is not correct, replace the power card.


The actuator does not work using the remote controls

Check that:

- The wiring to terminals 32, 35, and 36 is correct.
- There is no short circuit between the wires.
- The electrical load does not exceed 4W.
- If an external source is used, the voltage must be 24-120 VAC 50/60Hz or 20-125 VDC.


The motor is very hot and does not start

- Wait until the motor cools down before trying to operate the actuator again.
- Check that the number of operations per hour and their duration is suitable for the actuator service (see

the nameplate).

- Check that the valve operating torque is within the range of the unit’s designed operating torque.

The motor runs but the actuator does not move the valve

- Verify that the drive insert correctly fits in the actuator base.
- Verify that the drive insert has enough engagement with the valve stem.
- Verify that the keyed connections for all keyways is correct.
- Use the actuator handwheel and ensure the valve will move. If not, proceed as follows:

- Loosen the handwheel retaining screw
- Remove the handwheel
- Check the internal parts
- Reassemble the handwheel to the actuator

The valve does not seat correctly

- For position seated applications, ensure the travel limits are set correctly.
- Confirm the torque required by the application and increase the actuator output torque setting if

necessary.

- The internal trim of the valve may be damaged.

Excessive torque for valve operation

- Clean, lubricate and check the valve stem.
- Valve packing too tight
- Check that the internal valve is well lubricated and not damaged


The actuator does not stop in fully open or fully closed position