ElmoMC Power Supplies-TAM-20 User Manual

Page 24

Advertising
background image

Tambourine 20 Power Supply Installation Guide

MAN-TAMIG (Ver. 1.501)

|Mounting and Wiring the Tambourine 20|

www.elmomc.com

24

Table of Contents

3.4.5

Isolated AC Supplies (with an Isolation Transformer) Wiring
Diagrams

Figure 6: Single-Phase Isolated Source Connection

Caution:

When using a single-phase AC source, terminals AC2 and AC3 must be paired

together in a shared connection.

When using an isolation transformer, PR and PE must be connected together on the

Tambourine 20 side.

Figure 7: Three-Phase Isolated Source Connection

Caution

:

When using an isolation transformer, PR and PE must be connected together

on the Tambourine 20 side.