Chapter 4: initialization, 1 led diagnostics, Chapter 4 – ElmoMC Power Supplies-TAM-20 User Manual

Page 31: Initialization, Led diagnostics

Advertising
background image

Tambourine 20 Power Supply Installation Guide

MAN-TAMIG (Ver. 1.501)

|LED Diagnostics|

www.elmomc.com

31

Table of Contents

Chapter 4:

Initialization

4.1 LED Diagnostics

Figure 11: Power LED Indicators

The following indication LEDs are mounted on the front panel of the Tambourine 20 (Figure 11):

LED

Color

Indication

POWER

Green

Internal supply presence

SHUNT ON

Red

Shunt is on (blinks whenever the shunt is activated)

FAULT

Red

Shunt is inhibited due to:

A DC bus level that is higher than the shunt

threshold point

A duty cycle limitation

Wait a couple of minutes to exit the fault state.

The LED will switch OFF. Then reinitialize the system.

Advertising