Replacing the HPL lamp

A lamp must be installed before you use the luminaire.

Step 1:

Disconnect power to the Source Four jr / jr Zoom CE before installing the lamp.

Step 2:

Loosen the knurled bolt on the back of the lamp housing and pull the housing out.

Step 3:

Holding by the base, remove the HPL lamp from its box.

Step 4:

Align the flat sides of the lamp base with the retention brackets on either side of the

socket as shown in

Figure 3

.

N o t e :

Verify that the HPL lamp you intend to install is suitable for your facility’s voltage;

115-, 120-, 230-, and 240-volt HPL lamps are available. See

HPL lamp table, page

4

. Operating HPL lamps above their rated voltage reduces lamp life and can cause

premature lamp failure.

W A R N I N G :

Let the lamp cool before replacing.

C A U T I O N :

Use caution when installing or replacing any lamp.
When installing/replacing lamp, be sure to point the lamp away from your face and

away from others before inserting it firmly into the assembly.
This may prevent injuries if the lamp should break.

N o t e :

To avoid premature lamp failure, do not touch the lamp glass. If you do, clean it

carefully with isopropyl alcohol and a clean lint-free cloth. Allow to dry before

operation.

HPL lamp

Lamp retention

brackets

Figure 3

Knurled bolt

Lamp housing

Lamp retaining clip

INCORRECT

CORRECT

Advertising