Focus knob positioning, N o t e – ETC Source Four PARNel CE User Manual

Page 8

Advertising
background image

6

Source FourPARNel CE User Manual

English

Step 3:

Holding by the base, remove the HPL lamp from its box.

Step 4:

Align the flat sides of the lamp base with the retention brackets on either side of the

socket as shown in

Figure 3

.

Step 5:

Push down on the lamp base until the lamp seats firmly. When properly installed, the top
of the lamp’s base will be even with he top edges of the retention brackets.

Step 6:

Press lamp retaining clip across lamp base to secure.

Step 7:

Reconnect the Earth continuity cable. Reinstall the lamp housing by aligning the bolt hole

and tightening the knurled bolt.

Focus knob positioning

To adjust focus knob tension, loosen or tighten the focus knob screw. See

Figure 4

.

C A U T I O N :

Use caution when installing or replacing any lamp.
When installing/replacing lamp, be sure to point the lamp away from your face and

away from others before inserting it firmly into the assembly.
This may prevent injuries if the lamp should break.

N o t e :

To avoid premature lamp failure, do not touch the lamp glass. If you do, clean it

carefully with isopropyl alcohol and a clean lint-free cloth. Allow to dry before

operation.

C A U T I O N :

Improperly installed lamps cause premature lamp failure and socket problems.

C A U T I O N :

Lens rotation knob does not rotate 360°. Do not attempt to exceed limit.

INCORRECT

CORRECT

Focus knob in

flood position

Figure 4

Focus knob in

spot position

45° field angle

25° field angle

Focus knob

screw

Advertising