Lens identification, Changing a lens, Lens identification changing a lens – ETC Source Four PAR CE User Manual

Page 8: Removing a lens, Installing a lens

Advertising
background image

6

Source Four PAR CE User Manual

English

Step 7:

Reinstall the Earth continuity cable, then install the lamp housing by aligning the bolt hole

and tightening the knurled bolt.

Lens identification

Lenses for the Source Four PAR come in four versions. The type, or beam spread, can be identified

by the lens texture.

Changing a lens

Change lenses if they become cracked or badly scratched.

Removing a lens

Step 1:

Place the luminaire on a flat, stable work surface. Do Not remove or install lenses with

luminaire hanging.

Step 2:

Position the lens rotation ring with the spring clip at the top of the unit, directly below the

gel retaining clip. See

Figure 1

.

Step 3:

Tilt the front of the luminaire down at least 45°. See

Figure 7

.

Step 4:

Press the spring clip with your finger to release the lens.

Step 5:

Allow the lens to drop forward from under the clip.

Step 6:

When the lens drops, remove your finger, allowing the lens to slide forward until it rests

on the lens catchers. See

Figure 8

.

Step 7:

Carefully remove the lens.

Installing a lens

Step 1:

Position the luminaire with the front of the unit (lens side) facing you, and tilted slightly

upward. See

Figure 9

.

C A U T I O N :

Never operate the luminaire without a lens in place.

W A R N I N G :

Unplug the luminaire and allow it to cool down before attempting to change

a lens.

MFL

WFL

NSP

VNSP

Very narrow spot

Clear glass
15° Round beam shape

Narrow spot
Stipple glass (slight diffuse texture)
19° Round beam shape

Medium flood
Fewer facets, sized 6 x 22mm
21° x 34° Oblong beam shape

Wide flood
Many facets, sized 6 x 12mm
30° x 51° Oblong beam shape

XWFL

Extra-wide, or buxom, lens

Molded, borosilicate lens, multi-faceted

60° Round beam shape

(Optional)

Figure 6

Advertising