Programming

30

Patch Dimmers

You may use “and thru” functions to specify a selection or range of dimmers for patch

editing. Once your selection is made, press enter (

) to accept the selection and begin

editing. To remove the last selected dimmer from the selection, press the back button ( ).

Continue pressing the back button ( ) to clear all undesired dimmers from the selection.

Step 1:

Make a selection of dimmers for patching using either the touch wheel or the
numeric button pad. Press enter (

) to accept the selection.

In the examples below, the start address for a dimmer range selection is

highlighted and ready for editing. Each additional dimmer added to the

selection using the “and thru” functions adds to the selection. When a hi-

resolution Hi 16 bit dimmer is selected, both the high and low addresses are

selected for editing.

Step 2:

Assign a DMX address to the first dimmer in the selection using the scroll wheel
or the numeric keypad, the press enter (

). The focus changes back to the

dimmer number.

Assigning a DMX address to the first selected dimmer automatically assigns

consecutive numbering to the remaining selected dimmers based on the first

entry of the selection.

When dimmer doubling is enabled for a selected dimmer, the focus changes

to the second address (b) selection for the affected dimmers.

Step 3:

As needed, assign a DMX address to the second address (b) of the dimmer
doubled dimmer in the list and press enter (

) to accept the selection. The focus

changes back to the dimmer number.

Patch sACN Input

For example, assume the system is configured with 4 sACN universes (named 1, 2, 3, and

4, configured in the Arch Setup >

Network Settings

menu).

If two sources are available for universe 1, and two sources for universe 2, and 2 sources

for universe 3, nothing is controllable on universe 4 until one of the other six sources goes

away.

N o t e :

sACN patch editing only allows specification of the 4 sACN universes configured

for this Echo ACP. sACN 1 is available by default, the valid range is 1 - 63999. To

associate sACN universes to this Echo ACP, reference

Network Settings, page

41

.

Patch DMX Input

1:

111 a

111 b

2: 112

a 368

b

3: NA
4: 113
5: 114

H 115

L

6: 116

a 117

b

DIM DMX

1 AND 3

1:

111 a

111 b

2: 112

a 368

b

3:

NA

4: 113
5: 114

H 115

L

6: 116

a 117

b

DIM DMX

1 AND 3 THRU 6

1:

111 a

111 b

2: 112

a 368

b

3:

NA

4:

113

5:

114

H 115

L

6:

116

a 117

b

DIM DMX

Using “and”

Using “thru”

Patch sACN Input

1:

111 a

111 b

63999

2: 112

a 368

b

1

3: NA
4: 113

1

5: 114

H 115

L

1

6: 116

a 117

b

2

DIM

sACN

Univ

The Echo ACP manages all sACN inputs-to-dimmer patch

addressing for the enclosure.