Step 2:

Mate the transition cards with the ribbon cable edge connectors as indicated

below. Secure the ribbon cable connectors to the transition cards with wire ties.

The tie wrap binding needs to be on the top for an Upper board and on the

bottom for a Lower board for clearance. Clip wire tie ends for neatness.

Step 3:

Terminate the ethernet cable with the provided Ethernet Termination Kit (ETC

Part# 4101A2003). Follow the wire preparation and termination instructions

included with the kit. The cable will terminate in a small box (called a “biscuit box”

as referenced in a later step)

Backplane Settings

Upgrade kit backplanes ship from the factory with all DIP switches in the off (down) position.

You will have to set the DIP switches on the new backplane to match your rack. You will

also have to verify the termination switch settings.

a: Set both termination switches to “Off” (middle position) for all racks except the

last rack in your system.

b: Set the termination switches for the last rack in the system to “ON” (top

position).

c: Using a precision screwdriver, set the DIP switches to match your rack type

according to:

• number of modules (6, 12, 24, or 48)

• whether the rack has Advanced Features (AF)

Use the following chart to determine your required DIP switch settings:

“On” position = switch pushed to the top

DIP switch Number

Rack Model

1

2

3

4

5

6

7

8

SR3-6

On On

SR3-6AF

On

On On

SR3-12

On

SR3-12 AF

On

On

SR3-24

On

SR3-24 AF

On

On

SR3-48
SR3-48 AF

On

Match

the red

wire to

pin-1

and be

sure the

proper

side is

up

Wire tie the

connectors

together

Position of the

tie wraps

On top for Upper

On bottom for Lower

Set termination to “Off”

(middle position)

Set DIP switches