Operating instructions safety switch ces-ap-c.2-ch, Technical data for actuator ces-a-bdn, Dimension drawing – EUCHNER CES-AP-CL2-CH (Multicode) User Manual

Page 21: Only in combination with actuator ces-a-bdn-...)

Advertising
background image

Operating Instructions Safety Switch CES-AP-C.2-CH

21

Technical data for actuator CES-A-BDN

Parameter

Value

Unit

min.

typ.

max.

Housing material

Macromelt PA-based plastic

Dimensions

26 x ∅ 6

mm

Weight

0.005

kg

Ambient temperature

- 40

-

+ 70

°C

Degree of protection  

acc. to EN IEC 60529

IP67 / IP69K 

1)

Installation position

Active face opposite read head

Power supply

Inductive via read head

1) With flush installation

Dimension drawing

Caution!

Do not mount at temperatures below 0 °C.
The actuator can be damaged during mounting.

Switching distances
Operating distance for center offset m = 0

(only in combination with actuator CES-A-BDN-...)

Parameter

Value

Unit

min.

typ.

max.

Switch-on distance

-

19

-

mm

Assured switch-on distance s

ao 

1)

14

-

-

Switching hysteresis 

1)

-

2

-

Assured switch-off distance s

ar

- in x/z direction

- in y direction

-

-

-

-

40

60

Installation options

26

0

+0,5

Ø

30

* min.

30 *

30 *

6,1

0

+0,1

z

y

x

6

* metal-free zone

operating distance

Advertising