AS-i 3.0 PROFIBUS DP Gateway Double Master with integrated Safety Monitor for 2 AS-i networks

Technische Änderungen vorbehalten, alle Angaben ohne Gewähr

Id.-No.: 104137 Issue date - 9.6.08

EUCHNER GmbH + Co. KG

Seite

2

Kohlhammerstraße 16 D-70771 Leinfelden-Echterdingen

Tel. +49/711/75 97-0

Fax. +49/711/753316

.12A

classic mode / klassischer Modus

unterstrichene Werte sind anwählbar

underlined data can be selected

advanced display mode / erweiterter Display-Modus

Commissioning / Inbetriebnahme

LCS LIST OF
CORRUPTED SLAVES

RESET

|

1A-X

2A- |

3A-

4A-X

| 5A-X

....
30A-X |

31A-

| 1B-X

2B-X

| 3B-X

4B-X

| 5B-X

....
30B-X |

31B-X

FAULT DETECTOR

RESET

HISTORIC:
EFLT OVRV NOIS
ACTUAL:
EFLT OVRV NOIS
DUP ASI ADR:
0 |31B
HELP:
EFLT EARTH FAULT
OVRV OVERVOLTAGE
NOIS NOISE
DUP ASI ADR
DUPLICATE ASI
SLAVE ADDRESS

FLAGS: 0131 05
0000 0001
0011 0001
0000 0101
0000 0101
1 PERIPHERY_OK
0 OFFLINE_READY
0 AS-I_PWR_FAIL
1 NORMAL_OP.
1 CONFIG_ACTIVE
0 AUTO_ADDR_AVL
0 AUTO_ADDR_ASN
0 LDS.0
0 CONFIG_OK
1 AUTO_ADDR_ENA
0 OFFLINE
1 DATA_EXCH_ACT

LPF LIST OF
PERIPH. FAULTS
|

1A-X

2A- |

3A-

4A-X | 5A-X
....
30A-X | 31A-
|

1B-X

DELTA LIST
0- |

1A-X

2A-X | 3A-X
4A-X | 5A-X
....
30A-X | 31A-
|

1B

2B- |

3B

....
30B |

31B

SAFETY ORIENTED
SLAVES
|

1-XX

2-RX | 3-RR
4- |

5-

...
HELP:
X CHANNEL OK
R CH. RELEASED
ON OUTPUT ON
OFF OUTPUT OFF
? OUTPUT STATE
UNKNOWN

INT SAFETY MON

DIAGNOSIS
LAST DIAGNOSIS
VIEW CONFIG

EXT SAFETY MON
ADDRESS

10

MODE:

SORTED/V1

OK

ACTUAL CONFIG
0A | 1A-C
....
30A-X | 31A-D
| 1B-X
....
30A | 31B-F
HELP:
X O.K.
D DETECTED ONLY
UNKNOWN SLAVE
P PROJ. ONLY
MISSING SLAVE
C TYPE CONFLICT
F PERIPH. FAULT
A DUPLICATE ADR

SWID:
31256
FEATURE STRING: 2
.B..DC2
DOA.AUT
SAFE CPU A:
31166
SAFE CPU B:
31158
UART 1:
29642
UART 2:
29642

INT SAFETY MON
DIAGNOSIS
STATUS: CFG
...
ASI 1
SLAVES
| 1-XX
2-RX | 3-RR
....
AS-I 2
....
A COLOR

HELP:
X CHANNEL OK
R CH. RELEASED
ON OUTPUT ON
OFF OUTPUT OFF
? OUTPUT STATE
UNKNOWN
A DEVICE ADDRES

INT SAFETY MON
LAST DIAG CH1
STATUS: CONFIG
CH1.: OFF
A COLOR
32 RED
33 GREY
34 YEL FL
....
HELP:
A DEVICE ADDRES
+ CHANGED

MONITOR CONFIG
COMLETE
CONFIGURATION
FGDG
MON. VER.: 3.0
RELEASED
by SA
ON
2007/14/15
AT 14:43
RELEASE CODE:
81FE

SAFETY SLAVES
INT MONITOR
EXT MONITOR
FAULT DETECTOR
DELTA LIST
LCS
ERROR COUNTERS
LPF
FLAGS
ACTUAL CONFIG
AS-I MASTER

D I A G N O S I S

D I A G N O S I S

PROFIBUS
QUICK SETUP

SETUP
DISPLAY CONTRAST

AS-I SAFETY
DIAGNOSIS
SLAVE ADR TOOL
TEST

INT SAFETY MON

COMPLETE
DIAG INDEX

SLAVE ADDR. 4A
NO SLV.:
5
NO SLV. TEL.:
31
SLV. TEL. ERR.:
1
PERIPH. FAULTS:
2
PROTOCOL FAULT:
1

LAST DIAGNOSIS

CH1 COMPLETE
DIAG INDEX

EXT SAFETY MON

DIAGNOSIS
LAST DIAGNOSIS
VIEW CONFIG

MONITOR CONFIG
COMPLETE
CONFIGURATION
FGDG
MON.VER.: 3.0
RELEASED
BY

SA

ON

2007/11/15

AT:

14:30

RELEASED CODE:
81FE

EXT SAFETY MON
DIAGNOSIS
MODE: UNSORTED
CH1.: ON
...
ASI 1
SLAVES
| 1-XX
2-RX | 3-RR
4- | 5-
...
A COLOR
32 RED
HELP:
X CODE OK
R RELEASED
A DEVICE ADDRES

EXT SAFETY MON
LAST DIAG CH1
CH1.: OFF
A COLOR
32 RED
33 GREY
34 YEL FL
....
HELP:
A DEVICE ADDRES
+ CHANGED

EXT SAFETY MON

COMPLETE
DIAG INDEX

Safety Monitor Generation II

Safety Monitor Generation I

DIAGNOSIS
CH

1

OK

DIAGNOSIS
CH

1

OK

LAST DIAGNOSIS

CH1 COMPLETE
DIAG INDEX

ERROR COUNTERS
FOR SLV. DETAILS
PRESS OK ON ADDR

RESET
1A- 0
...
31A- 65535
1B- 34
...
30B- 0

AS-I CIRCUIT

1

AS-I CIRCUIT

2

AS-I CIRCUIT 1
AS-I CIRCUIT 2

AS-I CIRCUIT 1
AS-I CIRCUIT 2