Feature selections, How to navigate feature selection mode – Broan SSQTXE080 User Manual

Page 3

Advertising
background image

MODELS SSQTXE080 • SSQTXE110

Page 3

HOW TO SET SYSTEM LEVEL

Installer, homeowner, or building science expert may adjust Broan

SmartSense

®

ventilation system level.

1. System Level is only set in Master control. If home has more than

one installation then locate Master control; it is usually in master

bathroom or it should be clearly marked or documented.

2. Circle, mark or highlight System Level in Table A using home’s

square footage and number of bedrooms.

Note: Building science experts may calculate different rate based

on air infiltration measurements.

3. Circle, mark or highlight same System Level in Table B.
4. If home’s System Level is 30 then next steps are not necessary,

since System Level is set at factory to 30.

5. Put Master control in Program mode; press and hold SET button

for 3-seconds and then release it.

6. LED should be turning on and off every second (slow-blink); if it

is not then repeat step 5.

7. Press and release (tap) On paddle number of times from Table B.

If you tap On paddle too many times, tap Off paddle and System

Level will be reduced once for each Off paddle tap.

In order to reset System Level to 30, immediately after entering

Program mode (Steps 5-6), tap On paddle only once and then tap

Off paddle only once.

If you lose On paddle counts, tap Off paddle 9 times or more then

tap On paddle twice; System Level will be at 30; proceed with On

paddle taps from Table B.

8. Exit Program mode; press and release SET button.
9. After exiting Program mode, LED will fast-blink a number of

times.

LED will fast-blink the same number of times in three sets with a

slight pause in between each set.

10. Count number of times LED fast-blinks in a set.
11. Compare number of times LED fast-blinks in a set to number for

System Level in Table B.

12. If they are the same then System Level is set accordingly;

otherwise, re-adjust System Level starting with step 5.

FEATURE SELECTIONS

Vacation Mode: Used only with Master control. Temporarily disables

Broan SmartSense

®

system. Master control will not automatically

turn on its fan or any other system fan. After Feature Selection

mode exit, Vacation mode is cancelled when Master control On

paddle is pressed.
Disabled Mode: Excludes fan from automatic ventilation usage.

Does not affect manual operation and its ventilation is credited

toward system level accumulation. Master control will not turn it on

for automatic ventilation requirement fulfillment. If Master control

is put in Disabled mode, it will not turn on any fans for automatic

ventilation and recommended indoor air quality ventilation level is

not assured.
Automatic-Off: Automatically turns fan off 60-minutes after it was

manually turned on.
Delayed-Off: Turns fan off 20-minutes after Off paddle was pressed

once. In order to turn fan off immediately, press Off paddle twice.

HOW TO NAVIGATE FEATURE SELECTION MODE

Refer to diagram. First, make sure fan and LED are off by pressing

and releasing Off paddle. Vacation/Disabled Feature Selection

mode entry is accomplished by pressing On paddle until LED turns

on and off every second (slow-blink). Automatic-Off/Delayed-Off

Feature Selection mode entry is accomplished using same method

with Off paddle. Once either Feature Selection mode is entered,

pressing and holding associated paddle displays Feature’s status

using LED. Press and release associated paddle to toggle feature on

or off. When finished, press and release SET button to exit Feature

TABLE A

Floor Area (ft

2

)

Bedrooms

0 - 1

2 - 3

4 - 5

6 - 7

> 7

< 1500

30

45

60

75

90

1501 - 3000

45

60

75

90

105

3001 - 4500

60

75

90

105

120

4501 - 6000

75

90

105

120

135

6001 - 7500

90

105

120

135

150

> 7500

105

120

135

150

165

TABLE B

System

Level

ON

Taps

Fast

Blinks

165

9

11

150

8

10

135

7

9

120

6

8

105

5

7

90

4

6

75

3

5

60

2

4

45

1

3

30

ON &

OFF or

OFF 9x

& ON 2x

2

Push to

turn ON

Push to

turn OFF

S

mart

S

ense

®

®

SET

button

ON PADDLE

OFF

PADDLE

Feature Selection Modes

ON Paddle

Vacation

or

Disabled

OFF Paddle

Automatic-Off

or

Delayed-Off

Press and hold paddle (approximately 10-seconds)

until LED displays slow-blink then release.

ON

Paddle

Vacation

OFF

Paddle

Disabled

ON

Paddle

Automatic

-Off

OFF

Paddle

Delayed

-Off

Press and hold paddle to display Feature status.

Press and release paddle to toggle Feature on or off.

When done, press and release SET button;

LED and fan should turn on and then off.

If fan is on, press OFF paddle.

_

LED

Advertising
This manual is related to the following products: